Which UPS would be best for my CCTV system?

If you’d like to read about why we suggest you need a UPS for your CCTV system click here, if you’ve come from that article and you’d like to know which UPS system would be best for your CCTV system, we’ve got you… keep reading!!

We’re going to skip through all the technical lingo and get right down to the run times each UPS will provide your CCTV system.

 

We’ve made it easy for you by assuming the amount of camera’s, starting with the most common household setup, 4:

 

RUNTIME IN MINUTES

4 x camera & NVR (80 watts)8 x camera & NVR (160 watts)16 x camera & NVR (200 watts)
Eco-Alto 600va UPS for CCTV Camera Systems352816
Eco-Alto 800va UPS for CCTV Camera Systems383119
Eco-Alto 1000va UPS for CCTV Camera Systems725628
Eco-Alto 1400va UPS for CCTV Camera Systems856036
Eco-Alto 2200va UPS for CCTV Camera Systems14511270

*All calculations are estimations only

*Calculations are based on standard cameras (10watts each) and NVR with 3T storage and a modem  (40watts).

*PTZ, temperature and Bullet or turret dome cameras have a higher load.

 

The Eco-range is our entry level product and could provide a long enough run time if a burglar were to turn the power off before attempting a break in.

If you’d like longer run times, we have a range designed for security cameras to achieve run times for up to 36 hours, you can read about our CamSecure range here.

For any other run times please visit or calculator or contact us and we will a happy to help.

 

 

What are the benefits of using an external manual Bypass on UPS installations?

Starting with the basics, what is an external manual Bypass?

 

An interlocking manual bypass is used to retain power to critical equipment during UPS downtime seamlessly.

In layman’s terms “Bypass” is to go around, in the context of a manual bypass used on UPS systems, the bypass allows the power to go around and isolate the UPS, which may be necessary in event of UPS downtime.

Below is a basic image demonstrating the use of an interlocking external manual bypass (if you’re require more technical info, please contact us)

UPS Bypass demonstration

In image 1 we see the UPS operating normally, image 2 demonstrates how the equipment would operate with the UPS in bypass, using an external Bypass.

 

What about the Bypass that is included with the UPS?

 

At PSS all of our online UPS come with an internal bypass :

  1. The bypass is internal
  2. The bypass is automatic

Australian standards state, for safety reasons, all manual bypasses need to be external to the UPS to isolate for service purposes.

Below are images showing the internal bypass.

  1. Position of the internal bypass
  2. The mimic clearly indicates if the UPS is Online or in bypass

 

 

 

 

 

 

 

 

 

 

So, what are the benefit of an external manual bypass over the internal bypass included with the UPS?

 

In Essence, not having an external manual bypass would be for the critical equipment to be switched of in the event of UPS downtime.

Corporations trust UPS systems on their most critical equipment, this is where the Interlocking external manual bypass allows seamless maintenance and repair on the UPS without any interruption to the critical equipment.

 

If you have any questions, please contact us